Sign In | Join Free | My himfr.com
Home > Temperature Test Chamber >

QT3-56A Thermal Shock chamber,Auto Defrost Function ThrQT3-56A ee-zone Temperature Test Chamber

    Buy cheap QT3-56A Thermal Shock chamber,Auto Defrost Function ThrQT3-56A ee-zone Temperature Test Chamber from wholesalers
     
    Buy cheap QT3-56A Thermal Shock chamber,Auto Defrost Function ThrQT3-56A ee-zone Temperature Test Chamber from wholesalers
    • Buy cheap QT3-56A Thermal Shock chamber,Auto Defrost Function ThrQT3-56A ee-zone Temperature Test Chamber from wholesalers

    QT3-56A Thermal Shock chamber,Auto Defrost Function ThrQT3-56A ee-zone Temperature Test Chamber

    Ask Lasest Price
    Brand Name : SINOWON
    Model Number : QT3-56A
    Certification : CE
    Payment Terms : T/T, L/C, Western Union
    Supply Ability : 20 Sets per Month
    Delivery Time : 30 - 40 Days
    • Product Details
    • Company Profile

    QT3-56A Thermal Shock chamber,Auto Defrost Function ThrQT3-56A ee-zone Temperature Test Chamber

    QT3-56A Thermal Shock chamber,Auto Defrost Function ThrQT3-56A ee-zone Temperature Test Chamber



    QT3-56A Thermal Shock chamber,Auto Defrost Function ThrQT3-56A ee-zone Temperature Test Chamber


    Thermal shock test chamber is used to test products in alternating extremes of high and low temperatures in order to observe changes in product characteristics and failure occurrence.
    QT3 series air-to-air thermal shock chambers circulate cold, hot, or ambient air as needed. The conditioned air is pre-cooled or pre-heated beyond the set point, allowing quicker recovery of the desired condition after transfer.


    QT3 Series Chambers Conform Following Testing Standards:
    ※ MIL-STD-883E Method 1011.9 Thermal Shock
    ※ MIL-STD-202G Method 107G Thermal Shock
    ※ JIS C 0025 Basic Environmental Testing Procedures Part 2: Tests, Test N: Change of Temperature
    ※ IEC 61300-2-47:2004 Fiber Optic Interconnection devices and passive components-Basic Test and Measurement Procedures – Part 247: Tests – Thermal Shocks
    ※ JEDEC STANDARD JESD22-A104C Temperature Cycling
    ※ GB/T 2423.22-2012 Environmental testing - Part 2: Tests methods - Test N: Change of temperature
    ※ Others related standards and test methods: SJ/T10186-91Y73, GJB150.5, GJB360.7, GB/2423.22


    Chamber Dimensions:

    Model

    Interior Dimension
    (W ×H × D)

    Interior Volume

    Exterior Dimension
    (W ×H × D)

    Specimen Loading Weight

    QT3-56A/B/C

    400 ×350× 400mm
    15.7”×13.8”×15.7”

    56L

    1450× 1950 ×1600mm
    57.1” ×76.8” ×63.0”

    2.5Kg

    QT3-80A/B/C

    500 ×400× 400mm
    19.7”×15.7”×15.7”

    80L

    1550× 2050 ×1600mm
    61.0” ×80.7” ×63.0”

    5.0Kg

    QT3-150A/B/C

    600 ×500× 500mm
    23.6”×19.7”×19.7”

    150L

    1650× 2150 ×1800mm
    64.9” ×84.7” ×70.9”

    7.5Kg

    QT3-225A/B/C

    750 ×600× 500mm
    29.5”×23.6”×19.7”

    225L

    1850× 2250 ×1800mm
    72.8” ×88.6” ×70.9”

    7.5Kg



    Specifications:

    Structure

    Pre-cooling Zone, Pre-heating Zone, Testing Zone
    (Selectable 2-Zone or 3-Zone Test for stationary object test)

    Damper Device

    Forced Air Damper

    Interior Material

    SUS#304 Stainless Steel

    Exterior Material

    Stainless steel with environmentally baking paint

    Testing Shelves

    Stainless Steel Plate

    Refrigeration

    Cascade Refrigeration System

    Cooling Method

    Water/Air Cooling

    Ambient Temperature

    5℃~30℃

    Pre-heating Temperature

    80℃~200℃

    Pre-cooling Temperature

    -40℃ (-60℃/-75℃)~-10℃

    High Temp. Shocking

    60℃~150℃

    Low Temp. Shocking

    A=―35℃~0℃
    B=―55℃~10℃
    C=―65℃~10℃

    Temp. Uniformity

    Less than ±2℃

    Transition time

    <10 seconds

    High Temp. Recovery Time

    RT℃~150℃/5min

    Low Temp. Recovery Time

    RT℃~-75℃/5min

    Pre-heating Time

    40min (30min for 56L)

    Pre-cooling Time

    80min (60min for 56L)

    Controller

    Powerful interactive LCD touch screen controller

    Setting Range

    Temperature: -200℃~300℃
    Time: 0H1min~9999H59min
    Cycle: 1~9999cycle

    Resolution

    Temperature: 0.1℃
    Time: 1min

    Control Method

    PID+SSR

    Power supply

    AC380V/50Hz/3P

    Accessories

    Cable Port, LCD touch screen controller, Power cable

    Security System

    Overheat Protector, Compressor overload protector,
    Controller protector, Motor overload protector

    Note:
    1. Ambient temperature of +23℃ and a cooling water temperature of +25℃
    2. During pre-heating, prevention for temperature heat-up may be worked
    3. Performance shown above conforms to IEC61300-2-47
    4. Temperature heat-up/pull-down time is applicable only during independent chamber operation

    Features:
    ※ Automatically setting of pro-cooled and pre-heated air.
    ※ Testing samples don’t move, cable port is available for power on testing.
    ※ Powerful interactive touch screen controller, easy operation and setting
    ※ High accurate temperature recovery with PID auto tuning
    ※ Auto defrost function


















































    Quality QT3-56A Thermal Shock chamber,Auto Defrost Function ThrQT3-56A ee-zone Temperature Test Chamber for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong Hoyamo Precision Instrument Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)